Incorrect anchor bolt placement 2 Aug 2012
Incorrect anchor bolt placement Some of these anchor bolts were set to low to accept the specified washers and allow the nut to be fully threaded. Notching of the sill plate to accommodate a washer and nut is not permitted unless designed. More importantly, note that there are two plates (the joint is under the coil of nails). There is not anchor bolt within 12 inches of the end of the plate to the right, a violation.
foundation wind
Incorrect anchor bolt placement Gallery: Gallery Description: Some of these anchor bolts were set to low to accept the specified washers and allow the nut to be fully threaded. Notching of the sill plate to accommodate a washer and nut is not permitted unless designed. More importantly, note that there are two plates (the joint is under the coil of nails). There is not anchor bolt within 12 inches of the end of the plate to the right, a violation.
Views: 2034 Loves: 0 love it! Tag Count: 2
Additional Info File Size: 93.56 KB Dimensions: 800x600 Created: 2 Aug 2012 Updated: 12 Aug 2012